Abstract
Surface ozone concentration and surface air temperature was measured hourly at three coastal sites, four low elevation inland sites and two high elevation inland sites in southwestern Sweden. Diurnal ozone concentration range (DOR) and diurnal temperature range (DTR) were strongly correlated, both spatially and temporally, most likely because both depended on atmospheric stability. Accumulated ozone exposure above a threshold concentration of x nmol mol-1 (AOTx) was estimated from time-integrated ozone concentration (as from diffusive sampling) and measures of ozone concentration variability. Two methods both estimated 24-h AOTx with high accuracy (modelling efficiencies >90% for x <= 40 nmol mol-1). Daytime (08:00–20:00) AOTx could not be equally well estimated. Estimates were better for lower AOT thresholds. Diffusive ozone concentration sampling, combined with hourly temperature monitoring, could be a valuable complement to ozone concentration monitoring with continuous instruments
Keywords
AOT40; ozone; ozone index; diffusive sampler; temperature
Published in
Environmental Pollution
2009, volume: 157, number: 11, pages: 3051–3058
Publisher: Elsevier
SLU Authors
UKÄ Subject classification
Environmental Sciences and Nature Conservation
Publication identifier
- DOI: https://doi.org/10.1016/j.envpol.2009.05.038
Permanent link to this page (URI)
https://res.slu.se/id/publ/26246