Skip to main content
SLU publication database (SLUpub)

Research article2014Peer reviewedOpen access

Serum levels of unconjugated bisphenol A are below 0.2 ng/ml in Swedish nursing women when contamination is minimized

Gyllenhammar, Irina; Troger, Rikard; Glynn, Anders; Rosen, Johan; Hellenas, Karl-Erik; Lignell, Sanna

Abstract

In this study serum levels of bisphenol A (BPA) were investigated in primiparous women from Uppsala County, Sweden, sampled 3 weeks after delivery 1996-2011, in both yearly pools of serum (n = 39, temporal trend study) and in 208 individual samples also present in the pools. Possible contamination risks of BPA from blood sampling equipment and sample tubes, as well as from handling of the samples were evaluated. The unconjugated form of BPA was analyzed using a UPLC-MS/MS method with a limit of quantification (LOQ) of 0.2 ng/ml. The results show that the levels of unconjugated BPA generally were <0.2 ng/ml. The sampling equipment used when taking blood samples from the women and the tubes used for storage and processing of samples did not show any detectable BPA leakage. In the first analysis of the serum samples, unconjugated BPA levels >= 0.2 ng/ml were found in 12% of the individual samples and in 21% of the trend samples. However, in reanalyses of individual serum samples from the same aliquot or from new aliquots, samples with BPA levels >= 0.2 ng/ml in the first analysis did not have quantifiable BPA levels. Moreover, 11% of BPA spiked calibration samples (over 200) had higher levels than could be explained by the random error of the method. Thus BPA contamination of the biobanked samples probably occurred randomly during sample handling, pooling and processing. Equipment used for sampling of children and repeated blood sampling were leaking BPA. The results show the difficulties in analyzing compounds where samples are easily contaminated from exogenous sources. It also points out that it is questionable to use biobanked samples unless absence of BPA contamination from the sampling and storage materials, and during handling of the samples, can be proven. (C) 2013 Elsevier Ltd. All rights reserved.

Keywords

Bisphenol A (BPA); Serum levels; UPLC-MS/MS; Sampling equipment; Biobanked samples

Published in

Environment International
2014, Volume: 64, pages: 56-60

    UKÄ Subject classification

    Analytical Chemistry

    Publication identifier

    DOI: https://doi.org/10.1016/j.envint.2013.12.003

    Permanent link to this page (URI)

    https://res.slu.se/id/publ/84543