Skip to main content
SLU publication database (SLUpub)

Abstract

This paper describes the development and validation of the first fully automated method, based on on-line solid phase extraction-liquid chromatography-tandem mass spectrometry (on line-SPE-LC-MS/MS), for the determination of UV filters (UV F) and transformation products, with a wide range of physicochemical properties. The developed method was validated and applied to the analysis of the selected compounds in river water (RW), groundwater (GW), influent and effluent wastewater (IWW and EWW). Comparing with the off-line methodologies published so far the presented method provides several advantages including a shorter extraction time, lower sample volume and minimum manipulation. Low limits of detection were achieved for all the studied matrices,

Keywords

UV filters; Transformation products; On-line SPE; LC-MS/MS; Water analysis

Published in

Journal of Chromatography A
2013, volume: 1294, pages: 106-116
Publisher: ELSEVIER SCIENCE BV

SLU Authors

UKÄ Subject classification

Analytical Chemistry

Publication identifier

  • DOI: https://doi.org/10.1016/j.chroma.2013.04.037

Permanent link to this page (URI)

https://res.slu.se/id/publ/87427