Analysis of low-concentration gas samples with continuous-flow isotope ratio mass spectrometry: eliminating sources of contamination to achieve high precision

Cambaliza, Maria O. L.; Harlow, Benjamin A.; Ubierna, Nerea; Mount, George H.; Marshall, John D.; Evans, R. David

Abstract

Developments in continuous-flow isotope ratio mass spectrometry have made possible the rapid analysis of delta C-13 in CO2 of small-volume gas samples with precisions of <= 0.1 parts per thousand. Prior research has validated the integrity of septum-capped vials for collection and short-term storage of gas samples. However, there has been little investigation into the sources of contamination during the preparation and analysis of low-concentration gas samples. In this study we determined (1) sources of contamination on a Gasbench II, (2) developed an analytical procedure to reduce contamination, and (3) identified an efficient, precise method for introducing sample gas into vials. We investigated three vial-filling procedures: (1) automated flush-fill (AFF), (2) vacuum back-fill (VBF), and (3) hand-fill (HF) Treatments were evaluated based on the time required for preparation, observed contamination, and multi-vial precision. The worst-case observed contamination was 4.5% of sample volume. Our empirical estimate showed that this level of contamination results in an error of 1.7 parts per thousand for samples with near-ambient CO2 concentrations and isotopic values that followed a high-concentration carbonate reference with an isotope ratio of -47 parts per thousand (IAEA-CO-9). This carry-over contamination on the Gasbench can be reduced by placing a helium-filled vial between the standard and the succeeding sample or by ignoring the first two of five sample peaks generated by each analysis. High-precision (SD <= 0.1 parts per thousand.) results with no detectable room-air contamination were observed for AFF and VBF treatments. In contrast, the precision of HF treatments was lower (SD >= 0.2 parts per thousand). VBF was optimal for the preparation of gas samples, as it yielded faster throughput at similar precision to AFF. Copyright (C) 2009 John Wiley & Sons, Ltd.

Published in

Rapid Communications in Mass Spectrometry
2009, Volume: 23, number: 23, pages: 3868-3874 Publisher: WILEY-BLACKWELL

    UKÄ Subject classification

    Analytical Chemistry

    Publication identifier

    DOI: https://doi.org/10.1002/rcm.4325

    Permanent link to this page (URI)

    https://res.slu.se/id/publ/88092