Abstract

Objective To compare airway leak pressures after sealing peripheral lung biopsy sites with a resorbable ligation device (LigaTie) or thoracoabdominal (TA) staples. Study design Ex vivo study. Animals Four normal caprine cadavers. Methods Twelve lung lobes were harvested from 4 goats immediately after euthanasia. Each lobe was inflated to 20 cm H2O to test for leaks prior to biopsy. Pressure was then maintained at 10 cm H2O. Biopsy samples were obtained 3 cm from the periphery with a resorbable ligation device or a TA stapler (n = 6 per group). After biopsy, inflation pressure was slowly increased to 40 cm H2O while lungs were submerged in water. The pressure at which bubbles were first seen was recorded as the airway leak pressure. The length, width, volume, and weight were recorded for each biopsy sample. Results Five of 6 LigaTie biopsy sites sustained the maximum pressure of 40 cm H2O without leaking. One site leaked at 24 cm H2O. The TA-stapled sites sustained airway pressure to median 25.5 cm H2O (interquartile range, 23.5-26 cm H2O), and none of them reached the maximum pressure (P = .015). There were no differences in biopsy length, volume, or weight between groups. Conclusion Biopsy sites sealed with LigaTie withstood higher airway pressure without leaking compared with TA-stapled biopsy sites in normal cadaveric specimens. Clinical significance The LigaTie may be an alternative technique for sealing peripheral lung biopsy sites.

Published in

Veterinary Surgery
2019, Volume: 48, number: 5, pages: 845-849

    UKÄ Subject classification

    Surgery
    Clinical Science
    Medical Equipment Engineering

    Publication identifier

    DOI: https://doi.org/10.1111/vsu.13171

    Permanent link to this page (URI)

    https://res.slu.se/id/publ/97944