Skip to main content
SLU:s publikationsdatabas (SLUpub)

Sammanfattning

Conventional drinking water treatment is inefficient in removing a large fraction of known organic micropollutants (OMPs). Therefore more efficient treatment approaches are needed to limit exposure to OMPs via drinking water. Here, the OMP removal performance of a combination of ozonation/no ozonation and two types of granular activated carbon (GAC) was tested in a one-year pilot-scale study, alongside a study of full-scale treatment. The raw water was lake water with low ambient concentrations of OMPs. In total, 29 of 99 targeted OMPs (per- and polyfluoroalkyl substances (PFASs), pharmaceuticals and other OMPs) were detected (mean n-ary sumation OMPs = 57 +/- 16 ng L-1). Only a few OMPs were consistently removed in the full-scale process, while ozonation in the pilot experiment effectively removed 72% of detected compounds to levels

Publicerad i

Environmental Science: Water Research & Technology
2021, volym: 7, nummer: 3, sidor: 535-548
Utgivare: ROYAL SOC CHEMISTRY

SLU författare

UKÄ forskningsämne

Vattenbehandlingsbioteknik

Publikationens identifierare

  • DOI: https://doi.org/10.1039/d0ew00933d

Permanent länk till denna sida (URI)

https://res.slu.se/id/publ/111414