Sammanfattning

Background Peritoneal fluid (PF) analysis is a valuable diagnostic tool in equine medicine. Markers such as serum amyloid A (SAA) and haptoglobin (Hp) could facilitate the diagnosis of inflammatory abdominal conditions. Objectives The objectives were to (1) establish reference intervals (RI) for SAA and Hp in serum and PF in healthy horses, (2) compare SAA and Hp concentrations between healthy horses and horses with colic, and (3) to assess the correlation between serum and PF concentrations. Methods Serum amyloid A and Hp concentrations were determined by automated assays in prospectively enrolled healthy reference horses and horses with colic. RIs were calculated, group concentrations were compared by Student's t-test, and Pearsons correlation for serum and PF concentrations were determined. Results In healthy horses (n=62) the measurements for SAA were below the detection limit (0.5mg/L) in 94% of serum samples and 98% of PF samples. Horses with colic (n=61) had statistically significantly increased SAA concentrations in serum (P

Nyckelord

Abdominocentesis; acute phase protein; colic; reference interval

Publicerad i

Veterinary Clinical Pathology
2013, volym: 42, nummer: 2, sidor: 177-183
Utgivare: WILEY-BLACKWELL

SLU författare

UKÄ forskningsämne

Patobiologi

Publikationens identifierare

  • DOI: https://doi.org/10.1111/vcp.12031

Permanent länk till denna sida (URI)

https://res.slu.se/id/publ/87206